Our Vision for Health, Safety and Environment

 

We passionately believe that we can do every job, every day, without harm to people or the environment.

 

Alberta Envirofuels HSE Policy 

  

News and Updates

March 2008

 

September 2007

AEF updated status of Approval compliance and Enviro Vista Stewardship Commitments

 

Maintenance shutdown on September 12 for equipment repair and cleaning. Began controlled depressurizing of equipment to flare on September 11, and the plant started up again on September 14.

 

June 2007

AEF recognized by Alberta Environment as the first EnviroVista Champion in the province.

 

April 2007

AEF is a member of the Strathcona Industrial Association (SIA). One of the mandates of the SIA is to maintain the air monitoring network for Strathcona County and the east side of Edmonton. The results of this monitoring program can be found at the SIA website

 

November 2006

AEF completes 2.5 million man hours without an employee lost time injury.

 

June 2006

AEF recognition from Alberta Environment as one of 14 EnviroVista Leaders in the province

 

October 2005

AEF receives the Sherwood Park Chamber of Commerce Business award for Environmental and Occupational Safety

EnviroVista Program

 

This voluntary program sponsored by Alberta Environment provides Alberta industrial and manufacturing facilities and municipal water operations* with recognition for their environmental excellence.

*Eligible applicants are those operating under an Alberta Environment approval permit.

EnviroVista Leaders

EnviroVista Leaders: demonstrate a minimum five years of approved emissions performance; have an audited environmental management system in place and no Alberta Environment prosecutions in the past five years.

Continued recognition as an EnviroVista Leader requires program participants to renew their status annually.

For more on EnviroVista Leaders.

EnviroVista Champions

EnviroVista Champions have already met their Leader criteria and in addition have committed to a Stewardship Agreement 

For more on EnviroVista Champions.

 

HSE Loss Control Program

 

The primary focus of AEF’s Health, Safety and Environment (HSE) Program is to prevent incidents from occurring. Secondly, the Program strives to meet and exceed regulatory compliance.  AEF sets long-term goals, as well as yearly targets, for continuous HSE improvement.  When an incident does occur, our employees are trained to respond quickly to minimize the impact.  All incidents are investigated so that we can learn from them and make the necessary changes to prevent them from recurring.

 

Environmental Management and Control

 

At AEF, we regularly survey the plant ambient air, stacks, groundwater, soil, process equipment, wastewater and storm water to ensure compliance with regulatory and license limits and minimize environmental impact from the plant activities.  The following are our focus areas:

 

AIR

Examples of strategies used at AEF to ensure clean air include the following:

  • AEF is an active member of the Strathcona Industrial Association (SIA), which operates a network of ambient air monitoring stations in Clover bar, Sherwood Park, Elmjay, Gold Bar, Beverly, Clareview and Forest Heights.  Annual reports on local air quality are available at the SIA website.
  •  We conduct ambient surveys at our plant four times a year.
  •  Leaks from process equipment (Fugitive Emissions) are controlled through proper selection of valves, seals, flanges etc. etc., and regular emission surveys to identify leaking equipment.  We exceed the regulatory requirement for repair of leaks exceeding 10,000 ppm by setting an internal repair standard of 500 ppm.
  •  Our product storage tanks are equipped with double-sealed internal floating roofs to reduce emissions.
  • A network of 68 gas detectors is installed in the process area.  These continuously monitor for leaks around pumps, compressors and storage tanks.
  •  In 2006, we installed a meter on our flare line to monitor and minimize flare gases during normal operation.  If a plant upset does occur, process gases are vented to the flare to ensure that equipment is kept within safe operating limits.

Water

Examples of strategies used at AEF to ensure clean water include the following:

  • We conduct groundwater surveys four times a year: a network of 50 groundwater monitoring wells is installed throughout the plant site to ensure that groundwater is not being contaminated and/or that no pollutant is migrating offsite.
  •  Process wastewater, as well as runoff in the process area, is collected at the wastewater ponds.  After testing for quality, the wastewater ponds are discharged to the sanitary sewer for further treatment at the City of Edmonton Gold Bar Wastewater treatment plant
  • Clean runoff from the undeveloped areas of the plant, or outside the process area, are collected through a ditch system into the Storm water Pond, and tested before being released into the surrounding watershed.
  • We practice water conversation and achieve process cooling by using closed-circuit glycol coolers and fin-fan air coolers.  We do not use water from the river for process cooling.

Waste Management

Examples of strategies used at AEF to ensure wastes are handled properly, include the following:

  •  All wastes that require offsite disposal are identified and/or tested to ensure that they are properly classified and disposed according to regulations.
  •  Dryer adsorbents and catalysts are pre-cleaned through regeneration cycle before vessel change out, thereby reducing the quantity of hazardous wastes generated.
  •  Noble metal catalysts are returned to the supplier for metal recovery.
  •  Small quantities of similar wastes are combined to minimize handling, or returned to the plant process.

Resource Conservation

  •  We reuse process off gases as fuel for various heaters and boilers
  • We have an Energy Management Team to oversee energy management at AEF, and make recommendations to improve our overall energy efficiency and reduce green house gases. 
 
© Copyright 2005 - Alberta Envirofuels Inc. All rights Reserved